Tripp Lite PDUMV32HV 7.7kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.
Tripp Lite PDUMV32HV 7.7kW Single-Phase Local Metered PDU, 200-240V Outlets
Quick Code: Q316618Part Code: PDUMV32HVTripp Lite
Product Overview
Specification
Delivery & Returns
Technical Advice
The 70-inch (178-centimeter) PDUMV32HV 32A 200-240V 7.7kW Single-Phase Local Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers.
Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank's real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.
An ideal PDU for server rooms, network closets and data centers, the PDUMV32HV's all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The IEC-309 32A blue input plug with 10-ft. (3.05 m) cord connects to your facility's compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components' plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.
Digital Meters Help Prevent Overloads
Dual digital ammeters report real-time output current in amps
Visual monitoring of PDU load level prevents overloading as more equipment is connected
Distributes Plenty of Single-Phase Power
32A 200-240V 7.7kW local metered PDU
48 200-240V outlets—24 per bank (4 C19 and 20 C13)—distribute single-phase power to connected equipment
Dual load banks with separate 20A circuit breakers and digital ammeters
Special guards prevent breakers from accidentally tripping
Each bank is color-coded and labeled for convenient identification
Connects to AC Power Source
IEC-309 32A blue input plug with 10-ft. (3.05 m) cord for easy connection to main power source, generator or protected UPS
Included plug-lock inserts ensure components remain connected and powered
Included ground screw for equipment requiring chassis ground
Easy to Mount With or Without Tools
Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons (spare 2.9 mm and 4.6 mm buttons included)
Nut-and-bolt vertical installation possible with included mounting hardware
Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
- Dedicated 20A circuit breakers protect output
- Dual load banks with 24 outlets each (4 C19 and 20 C13)
- Ideal for server rooms, network closets and data centers
- IEC-309 32A blue input plug with 10-ft. (3.05 m) cord
- Ready for immediate toolless 0U installation
- Dedicated 20A circuit breakers protect output
- Dual load banks with 24 outlets each (4 C19 and 20 C13)
- Ideal for server rooms, network closets and data centers
- IEC-309 32A blue input plug with 10-ft. (3.05 m) cord
- Ready for immediate toolless 0U installation
Technical Description: 7.7kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.
Design
Rack capacity:The spase that device fill in rack.
0U
PDU types:A power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing, and remote monitoring and control by LAN or SNMP.
Metered
Logistics data
Products per master (outer) case:
1 pc(s)
Country of origin:Country where the device is made.
Taiwan
Operational conditions
Operating altitude:
0 - 3000 m
Operating relative humidity (H-H):
5 - 95%
Storage temperature (T-T):The minimum and maximum temperatures at which the product can be safely stored.
-15 - 60 °C
Operating temperature (T-T):The minimum and maximum temperatures at which the product can be safely operated.
0 - 50 °C
Packaging data
Package height:The distance from the top to the bottom of the packaging.
175 mm
Package depth:The distance from the front to the back of the packaging.
1927.1 mm
Package width:The distance from one side of the packaging to the other.
245.1 mm
Package dimensions (WxDxH):Dimensions of the packaged product (Width x Depth x Height).
68.8 x 64 x 177.8 mm
Package weight:Weight of the packaged product.
7.98 kg
Ports & interfaces
AC outlet types:The type of outlet for AC electricity.
C13 coupler, C19 coupler
Power plug:A power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
IEC309
AC outlets quantity:The number of sockets in the device where AC electrical power can be connected.
48 AC outlet(s)
Power
Nominal output voltage:The voltage which the manufacturer states that the device can produce.
200-240 V
Maximum current:The greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
32 A
Nominal input voltage:The voltage which the manufacturer recommends that the device needs to operate normally.
230 V
Technical details
Master (outer) case GTIN (EAN/UPC):
10037332182811
Weight & dimensions
Weight:Weight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
5.9 kg
Dimensions (WxDxH):Dimensions of the product (Width x Depth x Height).
245 x 175 x 192.7 mm
Height:The measurement of the product from head to foot or from base to top.
1778 mm
Depth:The distance from the front to the back of something.
64 mm
Width:The measurement or extent of something from side to side.
55.1 mm
Fast & Reliable Delivery
- Free Standard Delivery on orders over £100 within 5 working days.
- Priority Delivery options: 3 working days for £4.98, or next working day for £6.99.
- Free Next Working Day Delivery for eligible orders, achieving a 95% success rate.
- Orders placed before 4:00 pm Mon-Fri are dispatched the same day.
- Delivery may require someone present to accept between 8 am and 6 pm, Mon-Fri.
- UK Only: Sorry, international delivery is not available.
Flexible & Secure Returns
- 14-Day Returns for unwanted goods.
- 30-Day Returns for faulty items, with extended support for issues arising post-30 days under the manufacturer's warranty.
- Hassle -free returns online or via customer service.
Special Notes:
- Delivery exceptions for remote areas may incur additional charges and longer delivery times.
- Missed deliveries? No worries. Two attempts made, with an option to collect from your local depot.
- Oversize or overweight items might need an extra charge; we'll inform you in advance.
Customer First Approach
- We understand things don't always go as planned. Whether it's a delivery query or return, our dedicated team at MoreCoCo is here to ensure your shopping experience is smooth and satisfying. Contact us for any assistance or inquiries.
Our Promise
- At MoreCoCo, your satisfaction is our priority. We're committed to delivering quality and reliability, making your shopping experience as convenient and trustworthy as possible.
PDUMV32HV Tripp Lite
0037332182814 B016A4CKC0
7.7kW Single-Phase Local Metered PDU, 200-240V Outlets (8 C19 and 40 C13), IEC-309 32A Blue Input, 10 ft. (3.05 m) Cord, 0U Vertical, TAA, 70 in.
£454.99 and
In stock
SKU: PDUMV32HV